Login
Home > UPS Solutions > 3Phase UPS > 3Phase UPS > 15U Platinum Modular E 90KW Frame. Including STSW Controller. No Battery & No

15U Platinum Modular E 90KW Frame. Including STSW Controller. No Battery & No

Model: PSPM90KE

POWERSHIELD 15U Platinum Modular E 90KW Frame. Including STSW Controller. No Battery & No Modules. Requires PSPM90KCAB Battery Cabinet. 1000x514x760 (LxWxH) 80KG.

The PowerShield PSPM90KE Platinum Modular E UPS is a high-efficiency online double conversion UPS designed to provide reliable power protection for critical equipment. Built for demanding applications, it is suitable for environments such as data centres, manufacturing, hospitals, military & mining facilities.

Designed with scalability in mind, the PSPM90KE supports modular power expansion up to 90kW. Its flexible battery configuration, N+1 redundancy capability & service-friendly modular design make it a practical solution for sites requiring dependable backup power, future expansion & reduced maintenance downtime.

Features

  • High Efficiency Online Double Conversion
    Uses true online double conversion technology to deliver stable, reliable power protection with efficiency of up to 96%, helping reduce overall Total Cost of Ownership.
  • High Scalability
    DSP control, modular design & parallel technology allow the UPS system to expand as power requirements grow, simplifying future power upgrades.
  • Unity Output Power Factor
    Delivers unity output power to provide maximum usable power capacity for mission-critical loads, including modern servers & IT equipment.
  • Modular Design
    Modular power, static switch & battery design makes maintenance & replacement easier, helping reduce Mean Time To Repair while improving overall system reliability.
  • Flexible Battery Configuration
    Supports 32, 36 or 40 batteries per string, giving installers flexibility to configure the UPS based on site requirements & backup runtime needs.
  • Adjustable Charging Current
    Provides adjustable charging current for each power module, with up to 6A for 20kW modules & 8A for 30kW modules, allowing the system to be configured to suit battery requirements.
  • High Overload Capability
    Supports overload conditions of 110% for 60 minutes, 125% for 10 minutes & 150% for 1 minute, helping maintain operation during short-term load increases.
  • 5.7" Graphic LCD/Mimic Display
    Equipped with a 5.7" graphic LCD screen that provides clear information on UPS operation, alarms & control functions, with an easy-to-read mimic display.
  • N+1 Parallel Redundancy
    Allows the UPS to meet higher power demands through vertical expansion in a single rack enclosure, while supporting N+1 redundancy for improved reliability.
 
 